This article show a guide on how to use Nissan Consult 3 Plus to program keyless remote (T31/C11/K12).Hope it helps,and if you want to know more about Nissan Consult 3 Plus,check:Nissan Consult 3 Plus Projects.
Related Contents:
Nissan Consult 3 Plus Software Download
How to Install Nissan Consult 3 III Plus Diagnostic Software
Nissan Consult 3 Plus Clone Interface
Procedures:
1.From the CONSULT-III plus “All DTC” screen, select the “BCM”.
2.Select “MULTI REMOTE ENTRY”.
3.Select “Work Support”.
4.When the next screen appears, (section shown below) select “REMO CONT ID REGIST” function to program the remotes.
ID Code Entry Procedure
STEP 1
Close all doors (Observe the operation of the interior light with each door to ensure the door switches are OK).
STEP 2
Operate lock using the driver side door lock and unlock switch (on P/Window swassy.)
STEP 3
1.Remove and insert the key into the ignition key 6 times within 10 seconds (turning the key barrel switch from OFF to ON counts as 1 time).
2.Hazard warning lamp blinks and all door unlocks.
NOTE:On the sixth key insertion, keep the key in the cylinder with the key barrel switch ON.Does the hazard lamp blink and all doors unlock?YES >> GO TO STEP 4.NO >> GO TO STEP 1.
STEP 4
Within 3 seconds after the hazard lamp blinks and all door unlocks, turn ignition switch to the ACC position and operate lock using the driver side door lock and unlock switch.
STEP 5
1.Press the lock or unlock button of the keyfobto be added.
2.All doors unlock simultaneously.
3.Hazard warning lamp blinks and all door unlocks.
4.Key ID is registered.
Is key ID registered?
YES-1 >> When adding a keyfob: GO TO STEP 6.
YES-2 >> When ending registration: GO TO STEP 8.
NO >> GO TO STEP 1.
STEP 6
Operate lock using the driver side door lock and unlock switch.
STEP 7
1.Press the lock or unlock button of the keyfobto be added.
2.All doors unlock simultaneously.
3.Hazard warning lamp blinks and all door unlocks.
4.Key ID is registered.
Is key ID registered?
YES-1 >> When adding a keyfob: GO TO STEP 6.
YES-2 >> When ending registration: GO TO STEP 8.
NO >> GO TO STEP 6.
STEP 8
Open the all doors >> REGISTRATION END.
Here is the instruction show you guide on how to calibrate 2403 steering valve for…
This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…
This instruction show you guide on how to remove center joint and center frame for…
How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…
If the vehicle is oscillating on the wayline or catches up the wayline very slowly…
This is instruction show you guide on how to adjust cruise control release linkage for…