Categories: Auto Repair

Nissan Maxima 2017 Target Ignition Timing Adjustment by Launch X431 Throttle

In this instruction,car-auto-repair.com will show you guide on how to perform Nissan Maxima 2017 target ignition timing adjustment by Launch X431.For more Nissan projects,please follow this tag:Nissan Repair Cases.

 

Procedures:

Connect LAUNCH X431 Throttle to Nissan OBD port,then enter menu to select “Nissan”

Select “The vehicle with 16 pin”

Confirm VIN,select “OK”

Select “Automatic Selection”

Confirm your car VIN,year and model,select “OK”

Select “System Selection”

It will show you with the system information,just select “OK” to continue

Select “Special Function”

Select “Target Ign Tim Adj”

A system information screen will give you instruction:

Touch “Start” and adjust idle ignition timing under the following conditions:

Engine is warmed up

Loads(Air conditioner,Lights,ETC.) are off

Function is not normally required during the usual service procedure

Click “OK” to continue

Now you can select “Up” or “Down” to adjust the ignition time,and the select “Update” after an adjustment is made

Done!

More Launch X431 Training article,please check here:Launch X431 use guide

auto

Recent Posts

Scania Truck ALarm System APS 00001C Control Unit Error

Here is the instruction show you guide on how to solve Scania truck alarm system…

1 day ago

Doosan Stage V Engine U02A2 Timeout Error of CAN-Receive-Frame A1DEFI Solution

This instruction show you guide on how to repair Doosan stage V engine U02A2 timeout…

4 days ago

How to Solve Doosan Stage V Engine P011E Coolant Temperature Plausibility Fault

Here is the instruction show you guide on how to repair Doosan stage v egnine…

1 week ago

How to Use JPRO Diagnostics Performance Check Low Temp ATD Detroit Engine

This instruction show you guide on how to use JPRO Diagnostic software to performance check…

1 week ago

Scania Truck ALM 000800 Interrupted LIN Communicatin Siren

Scania Truck ALM 000800 Interrupted LIN communication with the siren.   Error identification LIN communication…

2 weeks ago

How to Solve JCB Excavator P0615-13 Starter Relay Open Circuit Error

Here is the instruction show you guide on how to solve JCB excavator P0615-13 trouble…

2 weeks ago