Perkins 1106D Engine Generation CID 0268 FMI 02 Trouble Repair

Perkins 1106D electric power generation EPG CID 0268 FMI 02 trouble repair guide.

Perkins-1106D-Generation-High-Press-Fuel-System-Error-Solution

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects one or more of the following conditions:
• One or more of the following configuration parameters are not programmed. The effect on the

ECM depends on the parameter.
• FLS or FTS
• Trim codes for the injectors
• Engine serial number
• All of the injector trim files are not loaded into the ECM. Engine performance and emissions are affected.

Preparations:

Perkins EST 2024A & 2023A & 2019A Software Free Download

Perkins SPI2 2018A EPC+Service Manual Free Download

Perkins Communication Adapter 3

 

 

System Response:
If equipped, the diagnostic lamp will flash and the derate lamp may come on. The fault is not logged.
The electronic service tool will display a list of the condition(s) on the “Active Diagnostics” screen that must be resolved.

Possible Performance Effect:
The ECM may limit the engine to low idle and/or the ECM may derate the power. Engine performance and emissions are affected.

Troubleshooting:
Use the electronic service tool to correct parameters that have not been programmed or parameters that have been incorrectly programmed.

Perform the following diagnostic procedure: “Flash Programming”

Results:
• OK – STOP

 

More trouble repair case for Perkins,pls refer to:Perkins Trouble Repair

Visited 1 times, 1 visit(s) today