Perkins 1106D Generation CID 0190 FMI 08 Trouble Repair

Here is the instruction show you guide on how to solve Perkins 1106D electric power generation(EPG) CID 0190 FMI 08 engine derated.

Perkins-1106D-Generation-High-Press-Fuel-System-Error-Solution

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the following conditions:

  • The ECM detected an intermittent loss of signal or a complete loss of signal from the primary
    speed/timing sensor for 2 seconds.
  • The engine has been running for more than three seconds.

 

Preparations:

Perkins EST 2024A & 2023A & 2019A Software Free Download

Perkins SPI2 2018A EPC+Service Manual Free Download

Perkins Communication Adapter 3

 

System Response:
If equipped, the diagnostic lamp will flash and the derate lamp will come on. The shutdown lamp may come on. The diagnostic code will be logged.

The ECM will use the signal from the secondary speed/timing sensor.

Possible Performance Effect:
The engine will be derated. If the signal from the secondary speed/timing sensor is also lost, the engine will shut down.

Troubleshooting:
This diagnostic code will detect a loss of signal from the primary speed/timing sensor.

Perform the following diagnostic procedure: “Engine
Speed/Timing Sensor Circuit – Test”

Results:
• OK – STOP

 