Categories: Auto Repair

Peugeot 408 2011 Steering Wheel Angle Sensor Calibrating by X431

This article show the guide on how to use Launch X431 to calibrate steering wheel angle sensor for Peugeot 408 2011.Any question to watch the video at end of article.

 

Procedures:

Enter the Launch 431 menu to select “Peugeot v43.00”

PEUGEOT series v43.00 All Systems

The software can diagnostic the elec control system of PEUGEOT,include engine,AT,ABS,SRS and AC.The operation is the same as the original scan tool.

Select “Manually Select”

Select “Cars”–>Select “408”

Select “408(2010.01-2014.09)”

Warning info:

Important:on vehicles that have hands-free starting and access,place the hands-free remote control in the electronic key reader so that all the operations and services for diagnosing that engine ECU are operational.

Tips:Reading VIN(Vehicle Identification Number)…

Read the VIN information,select “OK”

Select “Diagnosis”

Select “System Selection”

Select “Active and Passive safety”

Select “Active and passive safety”

The device will prompt you to “Switch On the ignition(Key in ‘ON’ position)”

Communicating,Please wait…

Select “ESP 8.1”

Warning info:

The ABS/ESP function deativates above 10 km/h when a diagnostic sessionis opened.Avoid any road testing that might require operation of the ABS/ESP during this,as the emergency braking assistance and electronic brake force distribution functions are no longer available.For safety reasons,the ECU cannot maintain communications with the diagnostic tool when the vehicle speed is greater than 10kph.if you exceed this speed,you must return to the global test menu,pres on validate to continue or on return to go back to the main menu.

Select “Special Function”

Now loading data,please waiting

Select “Pack reparation”

Select “Spare part”

Select “Calibration of the steering wheel angle sensor”

Please pay more attention to the hints,select “OK”

The steering wheel angle sensor has to be calibrated when adjusting the toe-in or when replacing the ESP ECU or the switch module at the steering wheel,working on the steering column or the steering column support or if the following fault appears or when the steering wheel angle sensor calibration impossible fault appears.

Before starting the calibration procedure itself,ensure that the wheels are in the straight line position.Two methods can be used to do this.Drive in a straight line:the vehicle should be driven along a level surface for approximately 100 meters and without any strong cross winds.The vehicle must be stationary after being driven,Taking as much care as possible not to alter the position of the steering wheel.Alignment on the test facility a Hunter type test facility ensures the front wheels are aligned.Validate to continue.

Please be sure that all conditions are satisfied select OK

It will start the calibration,select “OK”

The calibration was successful.Erase the faults then read the faults.The ‘steering wheel angle sensor calibration fault’ should no longer appear.Check that the zero position of the steering wheel has been set by driving for 1 or 2 km along straight roads and round bends(having disconnected the diagnostic tool).The fault LED should no longer illuminate.During this road test,there is no need to cause ESP regulation.Press no validate to return to the main menu.

The procedures has been finished,please log out.

 

Peugeot 408 2011 Steering Wheel Angle Sensor Calibrating Video Guide:

auto

Recent Posts

Fendt MT800E Tractor DEF Tank Temperature Does Not Change Solution

Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…

4 hours ago

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

1 day ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

2 days ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

3 days ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

4 days ago

How to Solve Doosan Machine P02EB Over Temperature Error

Here is the instruction show you guide on how to solve Doosan machine P02EB over…

5 days ago