This instruction show you Launch X431 programming Porsche Panamera level system after air spring replacement. More post about Porsche repair,please check here:Porsche trouble repair.
Caution:
Ensure the supply voltage is not under 12V during the operation.
Other operations should meet the requirements prompted.
Operation Guideline:
1.Select Porsche Version V21.80 or above.
2.Select automatic search
3.Select rapid test, click YES.
4.Select Level Control
5.Select version information.
6.After confirming the Porsche part number and diagnostic software number, click OK
7.Select special function.
8.Select replacement of air spring
9.Click [Charge an air spring]
10.Click OK, enter the interface and view the status and value of the battery voltage,ignition and engine speed
11.Click Next, select the second item of air spring selection, it appears 4 options of front left, front right, rear left and rear right
12.Select air spring selection
13.For example, select the second item [Front right], click [Start], the value of “Inflate air springs using pressure accumulator” and “Conclude filling process” changed from “wait” to “function completed”, and the status is OK
14.After the front right item, click [air spring selection] to select any one of front left, rear left and rear right. Click [Start]
15.To bleed the air spring, click [air spring ventilation] in the special function
16.Click OK, enter the interface and view the status and value of the battery voltage, ignition and engine speed
17.Click Next, select the second item of air spring selection, it appears 4 options of front left, front right, rear left and rear right
18.Select [Front right].
19.Click [Start], pay attention to the prompt, the value of “bleed air spring” changed to function completed and the status is OK
20.After the front right item, click [air spring selection] to select any one of front left, rear left and rear right. Click [Start], repeat the above two steps
More Launch X431 Training article,please check here:Launch X431 use guide
This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…
Here is the instruction show you guide on how to calibrate 2403 steering valve for…
This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…
This instruction show you guide on how to remove center joint and center frame for…
How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…
If the vehicle is oscillating on the wayline or catches up the wayline very slowly…