QSK60 G CM2358 Fault Code 1367 Pre-Oil Filter Pressure Sensor Circuit

Here is the instruction show you guide on how to solve QSK60 G CM2358 fault code 1367 Pre-Oil Filter Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source.

 

Related Contents:

INSITE 8.9.2 Engine Diagnostic Software

Cummings INLINE 6 Diagnostic Adapter

 

QSK60 G CM2358 Fault Code 1367 Pre-Oil Filter Pressure Sensor Circuit

Circuit Description

The engine control module (ECM) provides a 5 volt supply to the oil filter intake pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The oil filter intake pressure sensor provides a signal to the ECM on the oil filter intake pressure sensor signal circuit. This sensor signal voltage changes, based on the pressure before the oil filters. The ECM will detect a low signal voltage at operating conditions when the oil pressure may be slightly lower. The ECM will detect a high signal voltage during high engine speeds or operating conditions when the oil temperature is low.

 

Component Location

The oil filter intake pressure sensor is located on the oil filter housing.

 

Conditions for Running the Diagnostics

This diagnostic runs continuously when the keyswitch is in the ON position.

 

Conditions for Setting the Fault Codes

The Engine Control Module (ECM) detected the engine oil filter intake pressure signal voltage was out of range high.

 

Action Taken When the Fault Code is Active

The ECM illuminates the white MAINTENANCE lamp or flashes the amber CHECK ENGINE lamp, indicating a maintenance condition, immediately after the diagnostic runs and fails.

A default value for the engine oil filter intake pressure reading is used.

 

Conditions for Clearing the Fault Code

To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.

 

The fault code status displayed by the recommended Cummings electronic service tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.

 

The ECM will turn off the flashing amber CHECK ENGINE lamp / MAINTENANCE lamp immediately after the diagnostic runs and passes.

 

The “Reset All Faults” command in the recommended Cumming electronic service tool or equivalent can be used to clear active and inactive faults.

 

More repair case for QSK60 CM2358,please refer to QSK60 CM2358 Trouble Repair

 