Toyota Hilux 2010 G Chip 72 All Key Lost Program by OBD(OBDSTAR Key Master)

This post test OBDSTAR X300 key master on Toyota Hilux VIGO 2010 G chip 72 all key programming.

 

And here are some related content:

Toyota All Key Lost Programming

Toyota G Chip Programmig

Toyota Reiz 2010 G Chip All Key Lost Programming

 

Procedures:

Toyota G chip key have G stamped on key

Connect OBDSTAR Key Master to vehicle via OBD port,and enter system menu to select “TOYOTA/LEXUS”à”TOYOTA/LEXUS V31.09”

For all key lost,when you insert the new key the security light don’t off

Turn on the ignition with new key

Operate the OBDSTAR Key master to select “Immobiliser”

Select “Type 2(With G 72)”

Select “Reset immobiliser” (All keys lost)

Follow the prompt to switch ignition off

Then it will prompt to switch ignition on.

Switch the ignition off and remove the key,the press the “ENT” button to continue

Switch ignition on

Now the security light steady prompt

Switch ignition off and remove the key

Then OBDSTAR Key Master will show you below options:

Program keys as the following steps within 120 seconds:

A:Program 2 master keys and 1 sub keys.

1.Insert the first master key,turn on the ignition,and wait for seconds

2.Insert the second master key,turn on the ignition,and wait for 5 seconds.

3.Insert the third sub key,turn on the ignition switch,and wait for 5 seconds.Security light turn off,and programming is finished

B:Program 1 master key and 1 sub key:

1.Insert the first master key,turn on the ignition ,and wait for 5 seconds

2.Inser the second sub key,turn on the ignition switch,and wait for 5 seconds.

3.Turn on the ignition on switch quickly for 5 times.Security light turns off,and programming is finished.

 

C:Program 1 master key:

1.Insert the master key,turn on the ignition,and wait for second.

2.Turn on the ignition switch quickly for 5 times.Security light turns off,and programming is finished.

 

Now the security light is off when you turn on ignition,and it can start the engine.

auto

Recent Posts

Jungheinrich Junior AME13 Spring-Loaded Brake Electrical Connection Removal Guide

It is necessary step to remove electrical connection cable before you do disassemble or some…

2 days ago

How to Use Nexiq eTechnician Function Test?

Nexiq eTechnician provides a number of special tests to assist you with your vehicle diagnostic…

4 days ago

JCB JS140 Excavator P0523-68 Engine Oil Pressure Low Solution

Here car-auto-repair.com show you guide on how to repair JCB JS140 excavator P0523-68 trouble code…

5 days ago

Volvo Version 3 and 4 Truck Oil Pressure Test by Volvo Techtool

Here is the instruction show you guide on how to use Volvo TECHTOOL and VOCOM adapter to…

6 days ago

How to Solve Allison 3000 & 4000 Gen5 P071A Neutral at Stop Input Failed ON

This instruction show you guide on how to solve Allison 3000 & 4000 Gen5 transmission…

1 week ago

Mack and Volvo EPA13 GHG17 Engine NOx Conversion Monitor Test

This instruction show you guide on how to use JPRO TO perform Mack and Volvo…

2 weeks ago