Categories: Auto Repair

Vediamo Activate SA500 Auto Fold Mirror Retrofit for Mercedes Benz

This article show you guide on how to use Vediamo to activate SA500 auto fold mirror for Mercedes Benz.

 

Before use Vediamo to perform activation operation,you need to finish Benz mechanical fold mirror retrofit,the parts detail information you can query on Mercede Benz EPC software.

1.Right/Left fold mirror

2.Driver side switch panel (include fold mirror switch)

3.Right/Left door module (After 2010,not need replacement)

 

Vediamo Activate SA500 Auto Fold Mirror:
1.Connect Benz MB SD diagnostic tool to vehicle OBD port,then run Vediamo software.

2.After connection build connection,click “V-Ecoute”

3.Select “System”

4.Change folder

5.Broswe model cbf,example:204cbf

6.Select “CGW_204”

7.Click “OK” to continue

8.Doulbe click to connect to control module

9.Select “Coding”–>”Variant Coding”

9.Select “VCD_02_global_variant_coding” from service options

10.Select “500 spiegelanklappung not available” from “Current Coding” options

11.Select “500 spiegelanklappung”

12.Change the value from “not available” to “available”

13.Click “ECU Coding”

Now we need add auto fold mirror option on dashboard

14.Select “System”

15.Select control unit “IC_204”

16.Double click the control unit

17.Select “Coding”–>”Variant Coding”

18.Select “VCD_06_Menueakitivierung” from Service

19.Select “Spiegel anklappung bei Verriegelung (Menu_Mirror_Folding) nicht vohanden” from Current Coding

20.Select “Spiegel anklappung bei Verriegelung (Menu_Mirror_Folding) nicht vohanden”

21.Change value to “vohanden”(available)

22.Click “ECU-Coding”

Done!

auto

Recent Posts

Doosan Excavator P0408 Maximum EGR Rate Governor Deviation Error Solution

This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…

2 days ago

How to Calibrate 2403 Steering Valve for Fendt 800 S4 Tractor

Here is the instruction show you guide on how to calibrate 2403 steering valve for…

4 days ago

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…

7 days ago

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

1 week ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

2 weeks ago

How to Solve Fendt 800 Vario S4 wayline Running Slow

If the vehicle is oscillating on the wayline or catches up the wayline very slowly…

3 weeks ago