Volkswagen Tiguan 00349 Fault Code 09G TCM Shift Locked Repair

A Volkswagen Tiguan get the 00349 diagnostic trouble code,and the transmission can not work correctly,it seem that the transmission can not shift normally.More Volkswagen repair,check this tag:Volkswagen Repair Projects.

 

Preparation:

Newest ODIS-E Engineering 17.0.1/12.2.0/9.0.1 Free Download

08.2023 VW ODIS 23.0.5 & 7.2.1 & 5.2.7 Diagnostic Software Free Download

 

Use VW ODIS software to diagnose the VW Tiguan,get the 00349 trouble code.

00349:Solenoid Valve 10 (N283): Open or Short to Ground

 

Possible Symptoms

Shifting issues

 

Possible Causes

1.Damaged wiring harness

2.Failed Solenoid Valve

3.Failed TCM

 

Possible Solutions

Ohm test wiring harness

 

Special Notes

When found on the 6 speed 09G transmission:

Solenoid Valve 10 (N283) is also noted as The Pressure Control Valve 6 (N271)

 

After check wiring harness and solenoid valve,both of them can work normally.So it seem the TCM get trouble.

 

Remove Transmission Control Module from Volkswagen Tiguan,and open the cover to check the PCB board.And after appearence check and circuit measuring,it seem that the 99327-00005 communication chip damaged.

Replace a new 99327-00005 communication chip,and install all back on VW Tiguan.

Start engine,and test transmission work correctly.

auto

Recent Posts

Fendt MT800E Tractor DEF Tank Temperature Does Not Change Solution

Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF…

16 hours ago

HITACHI Construction 4JJ1 P0092 Fuel Pressure Regulator Control Circuit High

Here car-auto-repair.com show you guide on how to solve ISUZU construction 4JJ1 engine P0092 fuel…

2 days ago

How to Solve Perkins 1106D EPG Engine E398 Low Fuel Rail Pressure Error

Here is the illustration show you guide on how to solve Perkins 1106D electric power…

3 days ago

Deutz EMR3 Aassembly Inspection and Initialisation Test Guide

Here comes the instruction on how to use SerDia2010 to perform assembly inspection and initialization…

4 days ago

HITACHI ZX-5 Excavator No Load Max Differential Pressure Measurement Guide

This instruction show you guide on how to perform No load max differential pressure measurement…

5 days ago

How to Solve Doosan Machine P02EB Over Temperature Error

Here is the instruction show you guide on how to solve Doosan machine P02EB over…

6 days ago